Back to Basics 21 – The B10 Method

Back to Basics 21 – The B10 Method

The B10 method uses cycle test data to predict failure rates. 

A cycle test is done on a set of products (>20) until 10% of the units under test fail. The number of cycles until failure is called the B10 point.

The B10 number of cycles is converted to a…

Read More...

Back to Basics 22 – Cycle Testing

Back to Basics 22 – Cycle Testing

A cycle test is done on a set of products (>20) until 10% of the units under test fail. 

The number of cycles is converted to a time period by knowing the cycles per hour in any particular application. 

A failure rate is calculated by dividing the 10% failure…

Read More...

Cycle Testing for Static Applications? NO!

Cycle Testing for Static Applications? NO!

The failure rates of certain mechanical components used in solenoid valves, actuators, and valves vary substantially depending on operation. Seals such as O-rings, for example have fundamentally different failure modes when used in applications with frequent movement (dynamic) versus applications with infrequent movement (static). 